LayTec (www.laytec.de) has developed a new generation of pyrometers working at the wavelength of 400 nm: Pyro 400. The tool is the first real solution for direct surface temperature measurements of GaN layers. The temperature information provided by Pyro 400 is essential for further growth optimization and temperature control for future GaN LED and laser production.

 

pyro400-1.jpg Unlike conventional infrared pyrometry, which can only detect the temperature of the susceptor under the sapphire or SiC wafers, Pyro 400 performs pyrometry on the actual GaN layer.

 

At the wavelength of 400 nm GaN absorbs and thermally emits light, which enables pyrometry measurements of its surface temperature. The Pyro 400 system is specially designed for AIXTRON Planetary¢ç MOCVD systems. If the second view-port is available, it can be combined with other in-situ monitoring systems such as EpiCurve¢çTT for simultaneous measurements of wafer bowing and reflectance at two wavelengths (Fig. 1).

 

Pyro 400 was recently approved in production lines by industrial customers Fig. 1: Pyro 400 and EpiCurve¢çTT installed on Aixtron G4 and research institutions. Planetary¢ç system for simultaneous temperature, reflectance and wafer bowing measurements.

 

Fig. 2 shows typical linescan measurements: Pyro 400 monitoring the wafer temperature profile during a full revolution of the susceptor. The data provides direct access to the GaN surface temperature distribution across each wafer in a planetry reactor.

 

Together with the complementary reflectance and curvature data measured by EpiCurve¢çTT, the in-situ measurements give all information needed to optimize uniformity and LED performance. The data clearly shows that wafer bowing causes changes in temperature distribution and proves that the center of concave bowed wafers is hotter than the edges.

 

 

pyro400-2.jpg   

 

Fig. 3 demonstrates screenshots taken during GaN based laser structure growth. On the left side of the screenshots there are colorplots of the whole structures grown on 11 wafers: 1st layer ? GaN buffer, 2nd layer ? GaN/AlGaN superlattice, 3rd layer ? quantum wells.

The blue curves in the right upper corners show the time-resolved temperature at a certain point on wafer #11, the curves in the lower graph on the right show the temperature distribution over the wafers (red) and susceptor (grey) at a certain point of time. The position and the time can be chosen with the cross cursor on the 3-dimensional colorplot (black crossing lines).

 

pyro400-3.jpg

 

pyro400-4.jpg

 

According to the linescan in Fig. 3a taken during GaN buffer growth, the temperature in the center of the wafers is slightly higher than at the edges (convex red curves). This changes significantly when changing to different growth conditions for superlattice growth: the linescan of the AlGaN superlattice growth (Fig. 3b) shows that the temperature in the center of the wafers is lower than at the edges (concave red curves).

 

Pyro 400 is capable of measuring the slightest temperature deviations of the surface. Fig. 4 shows temperature curves of quantum well growth on 5 wafers (marked with different colors). Temperature variations of 1-3 K between different pockets can be resolved clearly.

 

pyro400-5.jpg

 

 

Using Pyro 400 it was also proven that the real surface temperature of GaN is sensitive to changes of carrier gas, rotation speed, and reactor pressure. These GaN surface temperature effects cannot be detected by conventional infrared pyrometry.

 

Fig. 5 shows as an example how the real temperature of the layer surface changes, when the pressure is reduced from 400 mbar to 50 mbar. The measurements were conducted in an AIXTRON Planetary¢ç MOCVD system with gas foil rotation. As the satellite rotation increases due to less pressure in the chamber, the flying height of the pocket increases, which cools the pockets by approx.

 

75 K (green curve). Yet the wafer surface temperature decreases even more by further 30 K (blue and red curves). These changes can be seen only with Pyro 400, whereas the process temperature measured by the light pipe (black curve) did not show any effects. Conventional infra-red pyrometry would only detect the effect on the pocket temperature (green curve).

 

pyro400-6.jpg

 

Additionally to these advantages, there are no emissivity oscillations during GaN buffer growth, which makes Pyro 400 an ideal tool for temperature feed-back control application.

 

In summary, Pyro 400 provides a new quality of temperature measurement with an unrivalled accuracy and will be of huge benefit in GaN based LED and laser production in the near future.

 

Copyright © Display Plus. All rights reserved.
ÆùƮŰ¿ì±â ÆùÆ®ÁÙÀ̱â ÇÁ¸°Æ®Çϱ⠸ÞÀϺ¸³»±â ½Å°íÇϱâ
Æ®À§ÅÍ ÆäÀ̽ººÏ ³×À̹ö ±¸±Û msn µÚ·Î°¡±â À§·Î°¡±â
Main Media Kit AD Rate Print Issues Show Daily Contact Us
USA: 24 Happy Valley Road, Pleasanton, CA 94588, USA (tel: +1-925-989-1144)
Korea: 1732 Hyundai HYEL, 463 Gongdeok-dong, Mapo-gu, Seoul, Korea (tel: +82-2-3473-6369)
Copyright © 2011 Display Plus. All rights reserved. mail to webmaster@displayplus.net